Accessories

SIT Insect Boxes

Designed to safely contain insects during irradiation, SIT Insect Boxes support even specimen distribution to help ensure consistent exposure throughout the treatment cycle. This enables reliable sterilisation outcomes while maintaining insect quality and viability. Available in a range of sizes.

SIT Insect Boxes

Conical Tube Holders

Designed to support consistent sample positioning for uniform dose distribution, helping ensure reliable and repeatable irradiation results. Available in 2-, 4-, or 8-position formats.

Conical Tube Holders

Holding Fixtures

Provide secure and stable specimen positioning to support consistent irradiation setup and procedural control. Available in two sizes for left flank, right flank, dual flank, and no flank use cases.

Holding Fixtures

Shields

Limit irradiation to targeted areas for controlled and localised exposure. Available for left flank, right flank, dual flank, no flank, abdomen, and cranial configurations.

Shields

Quad Fixtures

Enable simultaneous irradiation of up to four mice while maintaining focused exposure on the region of interest. Each set includes fixtures for left flank, right flank, cranial, and thoracic positioning, with individual components also available.

Quad Fixtures

Head & Spine Shield

Incorporates a Bite Bar and Nose Clamp assembly to support precise head positioning during irradiation. Both head and spine components can be removed to allow flexible configuration and positioning.

Head & Spine Shield

Pie Cages

Designed for total body irradiation workflows, Pie Cages provide stable specimen positioning and straightforward setup without the need for anaesthesia. Available for both mouse and rat models, with a range of configuration options.

Pie Cages

Fixed Collimators

Designed to deliver highly focused beam geometries for precise, targeted irradiation applications.

Fixed Collimators

CT Phantom

Constructed from tissue-equivalent materials, this phantom provides a reliable solution for independent imaging quality assurance (QA) testing.

CT Phantom

Plastimouse

Ideal for routine quality assurance of image-guided irradiation systems, these phantoms are biologically inert, structurally stable, and accurately replicate the anatomy of live specimens for consistent performance verification.

Plastimouse

External Dosimeter

The external dosimeter enables internal dose measurement through water or air-based readings, supporting straightforward calibration of the system’s internal dosimetry for improved accuracy and consistency.

External Dosimeter

Internal Dose Control

Measurement of the relative dose via parallel plate transmission chamber allows measurement of both the dose rate and cumulative dose for filtered beams.

Internal Dose Control